In digital dentistry and oral surgery, the registration of jawbone CT and intraoral scanner (IOS) data is essential for integrating internal bone structure with high-resolution dental surface geometry. However, this registration is challenging because the two modalities share only a limited region in common, and their true correspondence is generally unknown. This uncertainty has prevented rigorous quantitative evaluation of registration accuracy. In this study, we propose a pseudoIOS evaluation framework in which a point cloud emulating an intraoral scan is generated from CT data within the same coordinate frame, so that the transformation between them is known by construction and can serve as a true ground truth. Using this framework, we propose a coarse-to-fine registration method that combines a domain-generalizable local descriptor (GeDi) for initialization-independent global alignment with the iterative closest point (ICP) algorithm for local refinement, and also evaluate the influence of metal artifacts on registration. In experiments on seven cases, ICP alone frequently converged to local minima from a perturbed initial position, whereas GeDi$+$ICP maintained submillimeter mean absolute error (MAE) across all evaluated jaw and artifact conditions (0.55-0.69 mm). A three-way repeated-measures analysis confirmed that GeDi$+$ICP was significantly more accurate than GeDi alone. Metal artifacts had a statistically detectable overall effect, but their absolute impact on GeDi$+$ICP was small.
https://arxiv.org/abs/2608.07564
Care robots are increasingly being introduced into healthcare settings, raising important questions about their acceptance and ethical implementation. To better understand these challenges, this study investigates caregivers' perceptions of four categories of care robots: delivering supplies, helping patients into bed, monitoring vital signs, and assisting with mobility. We conducted a mixed-methods study employing a mixed-factorial design in which 298 caregivers from the United States, Mexico, and Chile evaluated all four robot categories. Quantitative measures integrated constructs from the Unified Theory of Acceptance and Use of Technology, the Cognitive-Affective-Normative model, and overall acceptance ratings. Qualitative data were collected through open-ended questions and analyzed using a literature-informed ethical framework. The results indicate that participants across countries generally evaluated care robots positively, particularly for logistical and physically demanding tasks rather than those requiring intensive interpersonal interaction. The qualitative findings provide further insight into stakeholders' views of the ethical implications of care robot use. Participants emphasized potential benefits such as reduced workload, lower risk, and greater patient autonomy, while also expressing concerns about dependability, the need for human oversight, and potential job displacement. Although many ethical concerns were shared across countries, participants differed in how they interpreted and prioritized them. These findings advance a context-sensitive and socially informed understanding of responsible design and implementation of care robots.
https://arxiv.org/abs/2608.02411
Chapter 6 of OpenAI's *Ten Advances in Mathematics and Theoretical Computer Science* claims an exponential parallel-repetition theorem for all finite two-player, one-round entangled games. Early in the proof, the chapter uses a quantitative greedy conditioning lemma. The lemma is meant to select a small set of coordinates (D) such that, after conditioning on winning every coordinate in (D), a randomly chosen remaining coordinate is won with average probability at least (1-\delta). The statement is correct, but the proof as printed contains a polarity error. Its continuation test is written in terms of average success, while the next step requires a coordinate with a large conditional failure probability. That implication is false, and even simple examples can leave the printed procedure without a valid next move. This note gives an explicit counterexample, identifies the intended continuation condition, and supplies a complete corrected proof. The repair is local: it leaves the statement of the lemma and the parameters used later in the chapter unchanged. It should not, however, be read as an independent verification of the main parallel-repetition theorem. More broadly, the example shows how a mathematically plausible AI-generated argument can hide a small but decisive reversal between complementary events.
https://arxiv.org/abs/2608.14673
We introduce a mathematical framework for shape comparison based on mapping functions from the shape domain to a common reference domain. This Push-Forward Transform enables invariant and robust comparison of shapes, preserving intrinsic geometric information. Quantitatively comparing shapes and their temporal evolution is a fundamental challenge in image analysis. Meaningful shape comparison requires representations that are invariant to transformations that do not alter shape itself, such as translation, rotation, reflection, re-parametrization, and uniform scaling, while remaining sensitive to intrinsic geometric variation. Existing approaches often rely on sensitive parameterizations, landmark correspondence, or learned representations that are difficult to interpret and reproduce. We show that the Push-Forward Transform (PF-T) applied to Signed Distance Functions (SDFs) yields a continuous representation that captures both boundary and interior geometry. We derive an interpretable morphometric that quantifies shape similarity and reveals features such as skeletal topology and rotational symmetries. The push-forward transform applies consistently to two- and three-dimensional shapes, extends to time-evolving geometries, and supports the joint analysis of shape and additional scalar fields defined over shapes, such as intensity or molecular signals. We present the mathematical formulation, describe an efficient algorithm, and benchmark the approach on 2D, 3D, and temporal data sets.
https://arxiv.org/abs/2608.02306
Realistic and diverse trajectory generation is central to enabling higher levels of vehicle automation. While rule-based and classical learning-based methods may struggle to capture the complexity of traffic behavior, generative models have already demonstrated in other fields that they can handle a comparable level of complexity. In this paper, we build upon previous work on generative adversarial network (GAN)-based semantic bird's-eye-view traffic generation and extend the proposed framework in several key aspects. We improve the semantic representation, replace the trajectory extraction procedure with a graph-based association method, and systematically investigate increasingly larger fields of view. In addition, we introduce a quantitative evaluation framework to assess hallucinations and object permanence in generated videos. Our experiments demonstrate that the framework generalizes to larger and more complex traffic scenes while maintaining statistically realistic trajectories and coherent spatial relationships between traffic participants. Within 150GPU hours of training and with inference times below 20ms for scenes of up to 20s, our results demonstrate that video-based GANs remain an efficient and scalable approach for realistic trajectory generation, even in substantially larger traffic scenes, making them well suited for downstream tasks such as prediction, planning, and simulation in automated driving.
https://arxiv.org/abs/2608.02289
In this paper, we propose ToW3D that enables precise and consistent control over 3D generative adversarial networks (GANs) with the Tug-of-War competition between shape deformation and appearance consistency. Existing point-based GAN editing methods such as DragGAN and GANWarping have yielded impressive performance for 2D image manipulation. However, as 3D generators present weaker generalization ability compared with 2D due to limited training data, they would suffer from drastic changes in global appearance when editing local areas of meshes. To address this, we design a pipeline of ``drag locally, shove globally'', which iteratively performs two optimization steps: 1) pull the point towards the target, and 2) push the structure and semantics back to the source. Specifically, we design a structure adaption module based on structure which guarantees the preservation of basic geometric properties, and a semantic preservation module that maintains semantic similarity across different views. Extensive qualitative and quantitative experiments demonstrate superiority of our ToW3D approach over prior methods in terms of appearance consistency and fidelity especially under large deformations.
https://arxiv.org/abs/2609.26078
On-policy distillation (OPD) provides teacher supervision on states visited by the student, reducing the distribution gap between training and inference. However, in multi-turn agentic tasks, student deviations may accumulate over time, gradually moving the trajectory away from states where teacher guidance remains effective. Our quantitative analysis further shows that high-disagreement states offer promising opportunities for teacher guidance, but determining whether such guidance is beneficial requires examining its effect on subsequent student trajectories. We propose FutureBridge-OPD (FTB), which executes a short teacher bridge at a high disagreement state and uses the resulting student continuation to assess whether the bridge increases the density of positive distillation signals relative to the teacher. On ALFWorld, WebShop, and ScienceWorld, under the main Qwen3-32B teacher to Qwen3-1.7B student setting, FTB outperforms vanilla OPD and TCOD by an average of 16.6 and 7.6 points, respectively, and remains effective across student scales and teacher settings. Our code is publicly available at this https URL.
https://arxiv.org/abs/2608.01953
Low-light image enhancement (LLIE) seeks to restore structural fidelity, natural color rendition, and proper exposure from images captured under inadequate lighting conditions. Recent state-of-the-art approaches, such as CIDNet, adopt a dual-branch architecture comprising a chrominance (HV) branch and an intensity (I) branch to separately model decoupled chromatic and luminance information within the HVI color space. However, these methods overlook the mutual interaction between intensity and chrominance components, which inherently limits their representational capacity and leads to suboptimal enhancement performance. To address this limitation, we propose the Conditional Mutual Information-Guided Network (CMIG-Net), which leverages conditional mutual information as a principled metric to quantitatively assess the contribution of chrominance features conditioned on the available intensity information. In particular, we design a Conditional Mutual Information Calibration (CMIC) module that generates a conditional information map, enabling region-adaptive recalibration of chrominance representations according to local illumination statistics. Furthermore, we introduce a Dynamic Dual-branch Information Restoration (D2IR) module, which adaptively governs bidirectional information flow between the intensity and chrominance branches, guided by both the conditional prior and the instantaneous restoration state. Extensive experiments on paired LLIE benchmarks demonstrate that CMIG-Net consistently outperforms CIDNet, achieving up to a 0.619 dB gain in PSNR, with a 0.382 dB improvement specifically on the challenging Sony-Total-Dark dataset.
https://arxiv.org/abs/2608.01886
This article addresses the relative scarcity of research tools for the corpus-assisted linguistic analysis of colour terms in literary texts. It describes the development of two multidimensional chromatic lexicons: one for Russian (224 entries) and one for English (141 entries). Lexicon construction involved sourcing colour vocabulary from specialised resources and research literature, comparing the two language inventories, manually checking translated candidates, and addressing language-specific morphological features. In addition to identifying colour terms and visual descriptors, the lexicons classify entries according to hue, saturation, and temperature. To demonstrate their practical application, a pilot study was conducted on purposively sampled corpora of poetry by Andrei Bely (20,373 tokens) and Emily Dickinson (28,479 tokens). All retrieved matches were checked in context and classified as Confirmed_chromatic, Ambiguous_visual, or Excluded. The analysis was implemented in two main stages: a strict analysis including confirmed chromatic lexis only, followed by a sensitivity analysis incorporating both confirmed and ambiguous chromatic lexis to determine whether coding decisions about borderline cases affected the main findings. The quantitative results indicated marked differences in the use of colour terms, visual descriptors, hue, saturation, and temperature. Specifically, the analysis revealed that confirmed chromatic terms occurred 3.4 times more frequently in the sampled Bely corpus than in the Dickinson corpus. These findings demonstrate the analytical value of a multidimensional approach, with the main contribution of this study being a transparent and reusable procedure for constructing and applying multilingual chromatic lexicons.
https://arxiv.org/abs/2608.01752
However, whether these judges truly evaluate the scientific substance of ideas or are influenced by superficial stylistic presentation remains an open question. To address this question, we propose SciStyleBench, a unified three-component benchmark for diagnosing and mitigating stylistic bias in LLM-based idea evaluation: (i) First, SciStyleStage, a three-stage evaluation environment that applies controlled stylistic perturbations to fixed scientific content across three settings no context, fixed-domain context, and open-domain retrieval context, covering 600 scientific ideas and 15 style variants, with 9,000 evaluation instances per setting; (ii) Second, SciStyleMetrics, a set of quantitative measures, including Style Bias Index (SBI), Substance Recognition Rate (SRR), and Adversarial Win Rate (AWR), to characterize how stylistic variation affects scoring stability, substance discrimination, and ranking robustness; (iii) Third, SciStyleExtractor, a plug-and-play evaluation module that separates presentation style from scientific content by predicting style type and deviation before style-conditioned evaluation, enabling us to assess whether style awareness reduces stylistic bias. Experiments on SciStyleBench show that direct LLM judges remain sensitive to writing style and struggle to distinguish scientific substance. In contrast, SciStyleExtractor reduces SBI from 0.566 to 0.501 while increasing SRR and AWR from 0.504 and 0.554 to 0.759 and 0.899, respectively. These results suggest that robust idea evaluation requires invariance to stylistic variation without sacrificing sensitivity to scientific substance. Overall, SciStyleBench provides a systematic framework for identifying, quantifying, and mitigating stylistic bias in scientific idea evaluation.
https://arxiv.org/abs/2608.01666
Generative artificial intelligence (AI) has transformed text-to-image synthesis, yet its ability to represent specialized engineering domains remains largely unexplored. As an exmaple in nuclear engineering, general-purpose foundation models frequently generate physically incorrect or conceptually inconsistent images because they lack domain-specific knowledge. This work presents one of the first systematic studies of domain adaptation for nuclear text-to-image generation through fine-tuning of open-source diffusion models. We curate a dataset of 1,000 captioned nuclear energy images spanning reactors, fuel cycles, radiation, and related concepts, and use it to fine-tune three state-of-the-art open-source models: Stable Diffusion XL (SDXL), SD-v3.5-Medium, and the flow-matching Flux.1 model. Their performance is evaluated using both quantitative image-similarity metrics and qualitative expert assessment against the corresponding zero-shot models. Fine-tuning substantially improves the fidelity of SDXL, provides only limited gains for SD-v3.5-Medium, and yields no measurable improvement for Flux.1, demonstrating that adaptation effectiveness depends strongly on the underlying generative architecture rather than model scale alone. We further compare the fine-tuned models against three leading commercial systems--GPT-Image-2, Gemini-3.1-Flash-Image, and Midjourney. Although GPT-Image-2 and Gemini generate convincing images for broad nuclear concepts, they frequently fail on specialized engineering prompts, where the fine-tuned open-source models produce more accurate and technically consistent outputs. These results establish domain-specific fine-tuning as a practical pathway for developing trustworthy generative AI tools for domain-specific applications.
https://arxiv.org/abs/2608.04030
Clinical acquisition in cardiac magnetic resonance (CMR) imaging involves obtaining cross-sectional planes of the heart along the radial and longitudinal directions. Despite these planes being 2D cross-sectional images of the heart, radiologists understand the 3D spatial and continuous temporal nature of the organ being imaged. The same can not be said about the conventional deep learning architectures used to process CMR images, which rely on in-plane and grid-based operations, and are hence unable to organically integrate information from all imaging planes. This paper builds upon previous work on neural implicit segmentation functions (NISF) to overcome unaddressed challenges in cardiac function modeling in the CMR domain. For a given subject, our architecture builds a shared 3D+time representations from all available acquisition planes regardless of orientation. By design, predictions along any imaging plane orientation are cross-sections of the same 3D representation, leading to spatio-temporal consistency across all slices. Moreover, our architecture makes the rotation and translation parameters of imaging planes learnable, allowing us to correct for the commonplace respiratory and patient motion between slice acquisitions under a rigid assumption. Furthermore, interpolation of intensities and segmentation can be performed in 4D at any desired resolution. We perform our study on a 120 subject sub-cohort of CMR imaging data from the UK-Biobank. Our in-plane segmentation performance is on-par with existing CMR segmentation methods and explore how the majority of failure cases arise from limitations in the ground-truth segmentation, for which our representations make predictions with better anatomical accuracy than its original training data. We also evaluate our motion-correction capabilities, displaying quantitative and qualitative improvements in slice alignment.
https://arxiv.org/abs/2608.00752
Large language models are increasingly viewed as a potential means of mitigating global health inequities, yet their outputs often reflect dominant high-resource medical traditions and provide limited coverage of traditional medical knowledge systems. Tibetan medicine, one of the world's four major traditional medical systems, has an independent and highly structured theoretical framework. When models lack grounded understanding of Tibetan medicine, they may fall back on dominant epistemic systems and distort the native knowledge structure during reasoning. However, quantitative tools for evaluating cultural bias in Tibetan medicine remain largely absent. To address this gap, we introduce TreeProbe, the first cultural-bias benchmark organized around the native Tree of Medicine framework in Tibetan medicine. It contains 4,719 expert-adjudicated items covering 467 diseases and 10 subtasks along the three roots. Experiments on representative LLMs show that current models remain limited in native Tibetan medical contexts and exhibit systematic external ontology drift. Further analysis reveals that models diverge in whether they drift toward biomedical or TCM reasoning, shaped by pretraining data composition and surface resemblance between TCM and Tibetan medicine. TreeProbe provides a diagnostic benchmark for developing medical AI systems that are both linguistically inclusive and epistemically fair. Code and data are available in an anonymous repository at this https URL.
https://arxiv.org/abs/2608.00640
Expressive piano performance depends on the sustain (damper) pedal, operated by foot, excluding players who cannot readily use their feet: wheelchair users and others with lower-limb impairments, small children, and some elderly or disabled players. We present bFaaaP (barrier-Free assist as a Pedal), an inclusive, foot-free interaction that operates the pedal from the angle of the player's head: a smartphone tracks head pose with on-device augmented-reality (AR) face tracking and streams a compact command over Bluetooth Low Energy (BLE) to a pedal device. Supported by patent examination, our central claim is not the head-to-pedal architecture (anticipated by prior art) but a quantitative, user-tunable control law -- the patentable "key" to a natural, expressive result: the player presets a small angular dead-zone (offset 3-10 degrees) and a multiplier (10-50), which together fix a secondary, pre-adjustable response speed that reproduces the pianist's intended pedalling. An engineering trick decouples the fast AR sampling from the slower BLE rate. Two co-equal realizations share one controller: a non-destructive robotic actuator for acoustic pianos (Pro), anchored by a pneumatic "airback" (our coined term for an inflatable air-braced anchor) that absorbs the reaction force without modifying the instrument; and an electronic sustain switch for digital pianos (Switch). In a human-subject Auxiliary Pedal Effect Evaluation (APEE) with 15 participants, bFaaaP significantly increased sustained-tone energy (p<0.01) and was statistically indistinguishable from a player's own foot (p>0.05), with no significant difference across classes; one participant with a leg disability and a tracheostomy performed successfully. With nothing worn on the face and fast setup, bFaaaP has run in formal public concerts (2018-2025). We release the full hardware and software as open source.
https://arxiv.org/abs/2608.00633
4D Gaussian Splatting (4DGS) can render dynamic scenes photorealistically. However, with limited viewpoint coverage, some spatiotemporal regions remain sparsely observed, leading to artifacts, particularly in scenes with large motion. Existing approaches leveraging generative models rely on heuristic virtual-viewpoint selection before refining rendered views. As a result, they cannot actively explore such sparsely observed regions. To address this issue, we propose a pipeline that actively selects spatiotemporal virtual viewpoints to improve 4DGS reconstruction. Our method selects virtual viewpoints for generative enhancement based on the rendering sensitivity and motion-aware observation density of 4D Gaussians, prioritizing views that alleviate observation sparsity. In the refined images, we filter out regions that conflict with captured observations or are likely to contain generative artifacts and then fine-tune 4DGS using only the reliable regions. We evaluate our method on multi-view video benchmarks using new train/test splits designed to induce observation gaps. Results show consistent improvements over prior viewpoint selection strategies and fine-tuning methods in both qualitative and quantitative evaluations, while reducing artifacts.
https://arxiv.org/abs/2607.29284
Medical image quality plays a critical role in diagnostic accuracy, especially in X-ray-based imaging modalities such as cone-beam computed tomography (CBCT), where image quality must be balanced against radiation dose. While expert visual evaluation remains the clinical standard for image quality evaluation, it is time-consuming, subjective and affected by inter-observer variability, emphasizing the need for reliable quantitative image quality assessment (IQA) methods. However, the development and validation of such IQA methods have been limited by the lack of publicly available CBCT datasets with expert image quality annotations. In this study, we provide the first open-access CBCT IQA dataset containing 1,764 annotated image slices acquired using systematic variations in image acquisition and reconstruction parameters. Three clinical experts graded the overall image quality and a predefined regions of interest (ROI) using a four-level scoring scheme. In addition, we benchmark 26 full reference- and no reference-based IQA measures against expert annotations and introduce an exploratory IQA measure-based ranking capable of distinguishing subtle image quality differences. This dataset introduced a standardized benchmark for future CBCT IQA research and provides a valuable resource for the development and validation of new IQA methods, enabling reproducible research and advancing CBCT IQA.
https://arxiv.org/abs/2607.29253
This paper proposes an automated classification method of COVID-19 chest CT volumes using improved 3D MLP-Mixer. Novel coronavirus disease 2019 (COVID-19) spreads over the world, causing a large number of infected patients and deaths. Sudden increase in the number of COVID-19 patients causes a manpower shortage in medical institutions. Computer-aided diagnosis (CAD) system provides quick and quantitative diagnosis results. CAD system for COVID-19 enables efficient diagnosis workflow and contributes to reduce such manpower shortage. In image-based diagnosis of viral pneumonia cases including COVID-19, both local and global image features are important because viral pneumonia cause many ground glass opacities and consolidations in large areas in the lung. This paper proposes an automated classification method of chest CT volumes for COVID-19 diagnosis assistance. MLP-Mixer is a recent method of image classification using Vision Transformer-like architecture. It performs classification using both local and global image features. To classify 3D CT volumes, we developed a hybrid classification model that consists of both a 3D convolutional neural network (CNN) and a 3D version of the MLP-Mixer. Classification accuracy of the proposed method was evaluated using a dataset that contains 1205 CT volumes and obtained 79.5% of classification accuracy. The accuracy was higher than that of conventional 3D CNN models consists of 3D CNN layers and simple MLP layers.
https://arxiv.org/abs/2607.28978
Evaluating LLM coding agents in algorithmic trading is difficult because static benchmarks risk data contamination and numerical backtest outputs require ground truth from actual code execution. We present Backtrader-Bench, a framework with two complementary pipelines. A deterministic multiple-choice question (MCQ) pipeline generates questions from backtest configurations across five trading strategies, 33 templates, and three difficulty tiers, with an independent checker that re-derives every answer. A generator-solver filtering pipeline autonomously mines harder questions: a generator writes questions verified by executable code, converts them to MCQs, and discards any that a no-tool solver can answer without code execution. We evaluate 11 models without tools (10 runs each) and four with-tools configurations on a 30-question curated set. Tool-augmented agents reach 90.0% accuracy in a single pass (GPT-5.5 and Opus 4.7), outperforming the best no-tools baselines (73.0%, averaged over 10 runs) by 17 percentage points. On 38 separately mined questions, no-tools accuracy drops further, with half the models falling to roughly random-chance level (25%). Beyond evaluation, the scalable MCQ infrastructure is designed to produce a training corpus for reinforcement learning, with the ultimate goal of building a specialized agent for quantitative trading workflows.
https://arxiv.org/abs/2608.11232
This paper proposes an automated classification method of chest CT volumes based on likelihood of COVID-19 cases. Novel coronavirus disease 2019 (COVID-19) spreads over the world, causing a large number of infected patients and deaths. Sudden increase in the number of COVID-19 patients causes a manpower shortage in medical institutions. Computer-aided diagnosis (CAD) system provides quick and quantitative diagnosis results. CAD system for COVID-19 enables efficient diagnosis workflow and contributes to reduce such manpower shortage. This paper proposes an automated classification method of chest CT volumes for COVID-19 diagnosis assistance. We propose a COVID-19 classification convolutional neural network (CNN) that has a 2D/3D hybrid feature extraction flows. The 2D/3D hybrid feature extraction flows are designed to effectively extract image features from anisotropic volumes such as chest CT volumes for diagnosis. The flows extract image features on three mutually perpendicular planes in CT volumes and then combine the features to perform classification. Classification accuracy of the proposed method was evaluated using a dataset that contains 1288 CT volumes. An averaged classification accuracy was 83.3%. The accuracy was higher than that of a classification CNN which does not have 2D and 3D hybrid feature extraction flows.
https://arxiv.org/abs/2607.28950
Transforming raw neuroimage archives into analysis-ready derivatives relies on three brittle stages: data standardization, modality-specific preprocessing, and quality control (QC). While individual neuroimaging tools are well developed, their orchestration requires project-specific scripts, environment-adaptive tuning, and labor-intensive manual QC. To address this, we introduce NeuroPilot, a multi-agent system that digitalizes the expertise of neuroimage processing, QC, and data management into three LLM-invocable skills: dcm2bids-skill, neuroimage-pre-skill, and qc-agent-skill. The LLM-driven agent autonomously orchestrates workflows, generalizing various infrastructure settings into a single configuration to achieve the highest scalability. Demonstrating the system's generalizability, we deployed NeuroPilot across 17 cohorts (>123,000 subjects) spanning infant to aging populations and multiple MRI modalities (structural, diffusion, functional). In practice, after standardizing data via the dcm2bids-skill, the agent dynamically routes datasets to the optimal neuroimage-pre-skill based on available modalities and cohort traits (e.g., dispatching T1w and fMRI data to fMRIPrep, or selecting specialized pipelines for infant cohorts). The qc-agent-skill then drives an evidence-based, semi-automated QC via a 3-D browser dashboard, utilizing a multi-tiered verification system to optimize failed cases and escalate complex issues for supervisor inspection. Quantitatively, our QC agent screened 558 production subjects, validating its automated flags against FreeSurfer's topology-defect metrics. The infant processing pipeline achieved a 100% (201/201) completion rate on QC-validated inputs. Importantly, NeuroPilot compresses the traditional 2--3 month timeline for training staff and processing complete datasets into a single week. NeuroPilot is deployed in this https URL.
https://arxiv.org/abs/2608.07541